大量Tenax-Ta吸附管出口
大量Tenax-Ta吸附管出口 詳細(xì)信息:
Tenax-TA吸附管對(duì)密閉環(huán)境中苯系物的吸附性能。方法依據(jù)《室內(nèi)空氣質(zhì)量標(biāo)準(zhǔn)》總揮發(fā)性有機(jī)物的測(cè)定方法和美國(guó)EPA TO-17標(biāo)準(zhǔn)方法,用Tenax-TA吸附管對(duì)配制的苯系物標(biāo)準(zhǔn)氣體進(jìn)行采樣,以保留時(shí)間定性,峰面積定量。結(jié)果該方法對(duì)苯系物測(cè)定的相對(duì)標(biāo)準(zhǔn)偏差在4.50%~9.51%之間,苯、甲苯、對(duì)二甲苯、鄰二甲苯的低檢出濃度分別為0.04,0.65,0.50和1.60μg/m3。當(dāng)采樣體積不大于3 L時(shí),Tenax-TA采樣管沒有穿透現(xiàn)象發(fā)生,苯系物通過Tenax-TA管吸附采樣后在室溫下可以保存40 d。結(jié)論 Tenax-TA吸附管對(duì)苯系物具有良好的吸附性能,而且設(shè)備簡(jiǎn)單,樣品保存時(shí)間長(zhǎng),適合于一些特殊環(huán)境中氣體的采集。
浩瀚色譜(山東)應(yīng)用技術(shù)開發(fā)有限公司建立環(huán)境空氣中低濃度苯系物的分析方法,研究解吸條件和分析條件.方法采用Tenax TA吸附/二次熱解吸/毛細(xì)管氣相色譜法.結(jié)果本方法對(duì)苯系物測(cè)定的相對(duì)標(biāo)準(zhǔn)偏差在4.30%~10.81%之間,具有良好的重現(xiàn)性.苯系物的加標(biāo)回收率大于94%.苯,甲苯,對(duì)二甲苯,鄰二甲苯的低檢出濃度分別為0.09,0.12,0.23,0.26μg/m3.結(jié)論本方法適合測(cè)定環(huán)境空氣中低濃度的苯系物.
規(guī)格:3.5in*1/8(美標(biāo)),國(guó)產(chǎn)6mm*120mm,6*90, 6*150
填充:200mg
浩瀚色譜(山東)應(yīng)用技術(shù)開發(fā)有限公司以質(zhì)量取勝,在2021年9月30日一次性出口Tenax TA采樣管1000多只,深受用戶好評(píng),浩瀚色譜,始終注重產(chǎn)品的質(zhì)量,浩瀚色譜,提供詳細(xì)的產(chǎn)品分析方案。
大量Tenax-Ta吸附管出口 測(cè)試譜圖:







A large number of Tenax-Ta adsorption tube outlets
A large number of Tenax-Ta adsorption tube outlets Details:
The adsorption performance of Tenax-TA adsorption tube for benzene series in a closed environment. Methods According to the "Indoor Air Quality Standards" total volatile organic compounds determination method and the US EPA TO-17 standard method, the prepared benzene series standard gas was sampled with Tenax-TA adsorption tube, and the retention time was qualitatively and the peak area was quantified. Results The relative standard deviation of the determination of benzene series by this method was between 4.50% and 9.51%. The minimum detectable co
ncentrations of benzene, toluene, p-xylene and o-xylene were 0.04, 0.65, 0.50 and 1.60μg/m3, respectively. When the sampling volume is not more than 3 L, the Tenax-TA sampling tube does not penetrate, and the benzene series can be stored for 40 days at room temperature after adsorption through the Tenax-TA tube. Co
nclusion Tenax-TA adsorption tube has good adsorption performance for benzene series, and the equipment is simple, the sample storage time is long, and it is suitable for gas collection in some special environments.
Haohan Chromatography (Shandong) Applied Technology Development Co., Ltd. established an analysis method for low-co
ncentration benzene series in ambient air, and studied the best desorption co
nditions and analysis conditions. The method used Tenax TA adsorption/seco
ndary thermal desorption/capillary gas chromatography. Results The relative standard deviation of this method for the determination of benzene series is between 4.30% and 10.81%, which has good reproducibility. The recovery rate of standard addition of benzene series is greater than 94%. Benzene, toluene, p-xylene, o-xylene The lowest detectable co
ncentrations are 0.09, 0.12, 0.23, 0.26 μg/m3, respectively. Co
nclusion This method is suitable for the determination of low-co
ncentration benzene series in ambient air.
Specification: 3.5in*1/8 (American standard), domestically made 6mm*120mm, 6*90, 6*150
Filling: 200mg
Haohan Chromatography (Shandong) Application Technology Development Co., Ltd. wins with quality. On September 30, 2021, it exported more than 1,000 Tenax TA sampling tubes at one time. They are well received by users. Haohan Chromatography always pays attention to the quality of products. Haohan Chromatography provides Detailed product analysis plan.
A large number of Tenax-Ta adsorption tube outlet test spectra:
本頁(yè)產(chǎn)品地址:http://www.okbaiwei.com/sell/show-9188619.html